Refrigerated air dryer ED-600FC, 90.0 Nm³/min
Specifications
- Air flow, Nm³/min
- 90.0
- Power input, kW
- 25
- Connection
- DN125
- Length, mm
- 1862
- Width, mm
- 1400
- Height, mm
- 1812
- Weight, kg
- 780
- Pressure dew point
- +2…+10 °C
- Working pressure
- 0.4–1.0 MPa
- Inlet air temperature
- 5–45 °C (FC) / 5–80 °C (HFC)
Description
Refrigerated air dryer ED-600FC, 90.0 Nm³/min is a model of the Refrigerated Compressed Air Dryer, 1.5–90 Nm³/min series. Key data: air flow 90.0 Nm³/min, power input 25 kW, connection DN125, length 1862 mm, width 1400 mm, height 1812 mm, weight 780 kg, pressure dew point +2…+10 °C.
ED-600FC specifications
| Air flow, Nm³/min | 90.0 |
|---|---|
| Power input, kW | 25 |
| Connection | DN125 |
| Length, mm | 1862 |
| Width, mm | 1400 |
| Height, mm | 1812 |
| Weight, kg | 780 |
| Pressure dew point | +2…+10 °C |
| Working pressure | 0.4–1.0 MPa |
| Inlet air temperature | 5–45 °C (FC) / 5–80 °C (HFC) |
Values separated by a slash refer to the FC / HFC versions. Power supply: 220 V 50/60 Hz single-phase for smaller models; 380 V 50 Hz three-phase for larger models.
Operating conditions: pressure 0.4–1.0 MPa, ambient temperature +2…+40 °C, inlet air temperature +5…+45 °C (FC) or +5…+80 °C (HFC).
Series features
- pressure dew point +2…+10 °C;
- copper-finned condenser for high heat transfer and subcooling;
- high-efficiency refrigeration compressors;
Applications
- air drying for the pneumatics of injection and blow molding machines;
- protection of pellet conveying from condensate;
- air preparation upstream of line filters;
Other models of the series
- Refrigerated air dryer ED-550FC / HFC, 80.0 Nm³/min
- Refrigerated air dryer ED-500FC / HFC, 67.0 Nm³/min
- Refrigerated air dryer ED-10FC, 1.5 Nm³/min
All models and the comparison table are on the series page Refrigerated Compressed Air Dryer, 1.5–90 Nm³/min.
Questions and answers
How does ED-600FC differ from the neighbouring models?
ED-600FC: air flow 90.0 Nm³/min, power input 25 kW, connection DN125. For comparison: ED-550FC / HFC: air flow 80.0 Nm³/min, power input 24 / 25.6 kW; ED-500FC / HFC: air flow 67.0 Nm³/min, power input 14.17 / 14.5 kW. Selection by air demand and pressure is on the series page.
Price on request. Send an enquiry and we will confirm the configuration of this model and prepare a quotation.
We will select equipment
for your production.